AKL-275UH
UV point-source replacement for configurations referencing USHIO NSHA275GT and the SP-11 irradiation unit.
- Rated power
- DC 275 W
- Optical reference
- 365 nm UVA
- Reference configuration
- USHIO NSHA275GT
A short-arc source with UV output for local adhesive curing and exposure configurations referencing PHOENIX SHP97A.

| Product model | AKL-97PHC |
|---|---|
| Product family | UV exposure & spot curing |
| Rated power | DC 210 W |
| Spectrum / application | UV band with visible output |
| Colour-temperature reference | — |
| Average-life reference | Approx. 2000 h |
| Reference lamp / configuration | PHOENIX SHP97A |
| Reference equipment | — |
| Drive configuration | DC; confirm the exact original power supply |
Values follow the existing model specification table. “—” means no value is provided. Average life is a reference, not a warranty or guaranteed operating duration. Final specification and compatibility follow the confirmed product and equipment configuration.
Match the adhesive’s required wavelength and dose to the actual UV output at the workpiece.
Confirm the mask, optical path and process conditions for local UV exposure.
Check the lamp code, power supply, reflector and optical coupling against the original installation.
Reference names are used for configuration comparison, not to imply original-brand manufacture or universal interchangeability. Replacement may require output verification and process calibration.

UV point-source replacement for configurations referencing USHIO NSHA275GT and the SP-11 irradiation unit.
Send the original lamp code, equipment model, label and connector photographs, operating requirements and quantity. We will confirm the product configuration and quotation.
Provide the original lamp code, equipment manufacturer and model, dimensions, electrical data and application. ZORSIKA can check the relevant industrial-lamp range; exposure, curing and inspection lamps must be matched to the actual equipment rather than ordered by power alone.
View the answer and related products →Similar dimensions are not sufficient. Confirm the intended spectrum, electrical operation, lamp geometry, connections and equipment specification; the approved replacement should be documented for the specific process and machine.
View the answer and related products →No. Confirm the equipment, original lamp code, electrical requirements, dimensions, base and process. ZORSIKA needs the actual application and part identification before assessing a replacement.
View the answer and related products →